Updated:
05 Mar 2010, 20:40
ET [original AT&T Worldnet Website begun 30 May 1996.] Update info on the top on ALL pages for your convenience. |
URL
http://berliner-ultrasonics.org/uson-0.html
(formerly http://home.att.net/~Berliner-Ultrasonics/uson-0.html moved to this domain on 05 Mar 2010) |
|
S. Berliner, III
Consultant in Ultrasonic Processing "changing materials with high-intensity sound" |
SONOCHEMISTRY * REACTION ACCELERATION * DISRUPTION
Specializing in brainstorming and devil's disciplery for new products and
{"Imagineering"}
Technical and Historical Writer, Oral Historian
HOMOGENIZATION * EMULSIFICATION * POLLUTION ABATEMENT
DISSOLUTION * DEGASSING * FINE PARTICLE DISPERSION
BENEFICIATION OF ORES AND MINERALS
CLEANING OF SURFACES AND POROUS MATERIALS
also see Keywords (Applications) Index
[consultation is on a fee basis]
reverse engineering and product improvement for existing products.
Popularizer of Science and Technology
|
Support and join the UIA
[New 2004 Logo |
|
|---|
On the main Ultrasonics Page (the preceding page):
Probe-type Ultrasonic Processing Equipment.
Brain Storming - bright ideas, pipe dreams, pie-in-the-sky?
On Ultrasonics Page A (the next page - created 19 Apr 01):
AL-1C - "CONDENSED GUIDE TO ULTRASONIC PROCESSING"
(A Layperson's Explanation of a Complex Letterhead).
AL-1P - "A POPULARIZED GUIDE TO ULTRASONIC PROCESSING".
(A Non-Technical Explanation of a Complicated Letterhead -
On Ultrasonics Page 1 (this page):
AL-1V - "A POPULARIZED GUIDE TO ULTRASONIC CAVITATION"
(A Non-Technical Explanation of "Cold Boiling".
TUBULAR HORNS (Radial Radiators)
CARE of TIPS (Radiating Faces).
Call for Contributions for Book.
AL-2 - "ULTRASONICS AND FINE PARTICLES -
BENEFICIATION OF SLURRIES AND FINE-PARTICLE SUSPENSIONS
[CERAMICS, COAL & ORES, COATINGS, COLUMN PACKINGS,
SINTERING, SLIPS].
AM-1 - "ULTRASONIC STERILIZATION and DISINFECTION".
UM-1 - "ULTRASONICS, HEARING, and HEALTH"
Foaming and Aerosoling - moved 28 May 02 from Page 1A.
Ultrasonic Propulsion (Propulsive Force) - Moving Material.
Ultrasonic Fountains - Atomization, Nebulization, Humidification,
Ultrasonics and Nuclear Fusion.
Quick Links for Ultrasonic Probe Manufacturers (moved 10 Jul 2002).
On the Ultrasonic Cleaning Page:
ULTRASONIC CLEANING {in process}.
On the ULTRASONICS GLOSSARY page:
ULTRASONICS GLOSSARY {in process}.
ULTRASONICS BIBLIOGRAPHY
CALL FOR CONTRIBUTIONS: I am writing a book on "High-Intensity Ultrasonic Technology and Applications" (intended for Marcel Dekker's "Mechanical Engineering Series", edited by Profs. Lynn L. Faulkner and S. Bradford Menkes). This book will focus on the practical application of power (high intensity) ultrasonics, the use of ultrasonic energy to change materials. Contributions are welcome.
[image from University of Washington, Applied Physics Laboratory (Lawrence Crum, Ph.D.)
"Cavitation" or "cold boiling" is easy to understand if you think about what the words "solid",
"liquid", and "gas" mean.
A solid is something hard that you can see and touch and hold; its molecules can not move in
relation to each other; they are "stuck together".
A liquid is something you can see and touch, but it runs through your fingers if you try to hold
it without a cup or a bowl; its molecules are free to move around each other but they can't move
apart. That means that they are "slippery"; they can flow.
A gas is something you can touch, like the wind moving across your hand when you stick it out
the window of a moving car, but you can't usually see it and you can't hold it at all without a
closed can or bottle; its molecules are free to move around and together or apart from each
other. They can expand or contract without limit.
The definition in physics of a solid is something whose molecules are rigidly bound together in
time and space, a liquid is something whose molecules are free to move around each other at a
fixed distance, and a gas is something whose molecules are free to move around each other and
to move closer together or further apart.
You know you can bend a solid, like bending a branch or matchstick or toothpick. If you
bend it too far, it snaps. If you bend a paper clip back and forth enough times, you can
break it, too; you "fatique" the metal or wear out the bond that holds the molecules together.
What you are doing in each case is called "exceeding the elastic limit"; you are bending it
further than it can bend without breaking. With a hammer, you can break a brick or a
small stone. With a big enough hammer or a wrecking ball, you can smash rock or boulders
or concrete.
Well, you can break liquids, too! You do it every time you break glass! Glass isn't
really a true solid; it is actually a very, VERY, VERY thick liquid, sort of like a
super thick syrup or molasses. If you look carefully at ancient window glass, you can see
that it has drooped; it has a bulge toward the bottom of the pane. That's because it is
flowing downhill; gravity is pulling it down even though it's held in the window frame.
"Silly Putty" is exactly the same thing, only not quite as thick; you can see it flow if you
wait long enough. But hit it or snap it and it breaks.
Just as you broke the paper clip by bending it back and forth slowly, you can break water (or
most other liquids) by jiggling it back and forth, only you have to do it very quickly.
By sticking a vibrating object into water, if you vibrate it far enough (a tiny fraction of an
inch) and fast enough (around 10,000 times a second), you can "fatigue" the water and break the
bond between the water molecules. But what does that mean? What was the definition
of a gas? Something whose molecules could move apart. So, if you move water
molecules apart, you have a gas, and the gas of water is steam. A steam bubble is
normally created by heating above the boiling point (212°F or 100°C). But we just
did it by fast jiggling, not by heating, so we "cold boiled" the water!
Next, we now have a steam bubble wandering around in a cold liquid, and that just can't be!
The steam has to condense (the way steam from a kettle or hot shower frosts a glass or mirror)
and that leaves an empty space behind, a "void" or "cavity", where the steam was. The
surrounding water molecules rush in to fill that cavity; when they reach the center of the
cavity, they collide with each other with great force. This is called "cavitation".
That makes the molecules bounce back, creating a "shock wave" which runs outward from the
collapsed bubble just like ripples in a pond when you throw in a pebble. The shock wave
can wear away metal; like the edges of an outboard motor propellor. Cavitation was
discovered by investigating why propellors wear out.
Where shock waves meet each other, they can cause more steam bubbles to occur and collapse,
creating even more cavitation. There, now you're an expert on cavitation!
© Copyright S. Berliner, III 1997 (all rights reserved) Updated: 09 July 1997, 09:35
Let me repeat here what I noted on a preceding page:
This discussion continues in more technical detail
Cavitation requires some discontinuity in the liquid, such as gas bubbles or dust motes, about
which the bubble forms. A theoretically pure liquid would require impractically high
power levels to initiate cavitation. Ultrasonic degassing initially increases the
efficiency of cavitation by removing air bubbles which absorb acoustic energy and damp
sonication.
Ultrasonic degassing is perhaps a slight misnomer, inasmuch as gases are forced both in and out
of suspension and solution by ultrasonic action. Degassing in an ultrasonic field occurs
when the rapid vibration of gas bubbles occasioned by the passage of acoustic waves from the
radiating surface through the liquid causes adjacent bubbles to touch and coalesce. As
this action progresses with time, bubbles grow to a size sufficient to allow them to rise up
through the liquid, against gravity, until they reach the surface, rise through, and pop (there
may be a more elegant scientific term but I am sure the reader will understand what is meant by
"pop").
A distinction should be made here between the bubbles which are formed by cavitation and those
which occur naturally in the parent liquid or are induced by ultrasonic action (sparging).
Cavitation bubbles, which range in size from infinitesimal to visible (40µm and up) appear only
when the radiating surface is activated and vanish apparently instantaneously when the power is
turned off (in actual fact, they vanish within a half cycle or 0.000025 sec. at 20KHz).
Naturally-occurring bubbles of entrapped air or other gases are most evident in freshly-poured
hot tap water as a cloudiness or in still water as small bubbles adhering to the undersurface
and the vessel walls. Sparged bubbles, those induced mechanically by external means, such
as by ultrasonic action at or near the gas-liquid interface (the surface) tend to float in the
liquid and even cause foam.
Coalescing of either type of bubble is fast and quite visible in water or other clear liquids
and is even visible in translucent liquids since it occurs throughout the bath and so occurs at
the walls and surface where it can be viewed. The assumption is made, perhaps
unwarrantedly, that the vessel is clear or provided with viewports or other means of viewing
what occurs in the liquid - such visibility is a prerequisite for visual determination.
Should visual examination of the process not be possible, other means of determination, such as
neutron radiography, may be employed.
Because a critical factor in successful degassing is that the bubbles grow, rise, and escape
through the surface, parameters such as temperature, viscosity, vapor pressures, and surface
tension are also critical. The distance bubbles must travel to reach the surface thus
becomes of interest and the process must be designed to allow for such transit time. In
order to provide for transit, the energy may be interrupted periodically, "pulsing" the
activity of the radiator. To further complicate matters, since cavitation causes both
sparging and coalescence, the energy level (intensity) must be carefully selected. These
are done empirically; in this area of endeavor, nothing beats cut-and-try experience, and it
can be done rapidly and conveniently.
Pulsing is most commonly done by means of a pulsing circuit provided integrally in the
generator of the leading brands of ultrasonic processors. These features generally
interrupt the low-voltage control circuitry and allow for variation of pulse interval and pulse
length. In degassing, short bursts at low to moderate intensity, followed by relatively
long recovery periods to allow bubbles to rise, suffice. Time ranges might be on the
order of a half a second on and ten or twenty seconds off for liter-batch quantities.
Providing a vacuum above the gas-liquid interface (surface) greatly enhances degassing and
requires both a pulse-free (constant pressure) vacuum source and a means of disposing of the
extracted gases if they are in any way environmentally unsafe.
NOTE: Bubbles that appear in the body of the sample liquid during sonication may
also represent sonochemical degradation products or high volatiles driven out by cavitation.
If these phenomena are possible, chemical analysis is recomended in critical processes.
: Flammable or
explosive volatiles may be driven out by cavitation and could ignite. Virtually no
sonication devices are explosion-proof and only extreme measures can render them even
explosion-resistant.
Ultrasonic degassing is a growing area of application, unfortunately held back more by details
of mechanical systems (and secrecy) than by the ultrasonic equipment available. From
analysis of dissolved oxygen and carbon dioxide content of soft drinks and wines and spirits to
production degassing of process lines, application of ultrasonic energy holds promise of
continued growth in this field.
Ultrasonic Bibliography Page 1 - Reference Books on Acoustics,
Vibration, and Sound.
Ultrasonic Bibliography Page 2 - Sonochemistry.
Ultrasonic Bibliography Page 3 - Selected Articles.
You are invited to visit the ULTRASONIC INDUSTRY ASSOCIATION home page.
THE CAVITATION BUBBLE
- bubble diameter approximately 1mm]
ULTRASONICS - continued
ULTRASONIC CAVITATION
[See the photo of a cavitation bubble at the top of this page
and the section, More on Cavitation, on page 2]
AL-1V
A POPULARIZED GUIDE TO ULTRASONIC CAVITATION
4-97
For more information, please contact S. Berliner, III.
in More on Cavitation on Page 2.
[Although NOT in the original monograph, reference is added here to the section on
Ultrasonics Page 6 re Explosion Resistance]
In continuous flow operations, some form of standpipe must be provided to prevent pumping
pressure from overcoming evacuation pressure, which might otherwise cause the process liquid to
flow out the gas outlet. The height of the standpipe is determined by the weight of the
liquid in it, which must exceed the process pressure and the base of the standpipe must be
located directly above the cavitation field. Save such a standpipe, elaborate separation
technologies must be employed.
(05 Mar 10)
I would also like to add that one of the most convincing demonstrations of the degassing power of ultrasonics has always been to put a cup of carbonated beverage (soda, pop) in an ultrasonic cleaner or to put a probe into the cup and activate the cleaner or probe; do NOT fill the cup, or be prepared to do a LOT of cleaning up. The action is very much like vigorously shaking a bottle of soda and releasing the contents; foam in every direction, instantaneously!

DISCLAIMER: The information given here is generic and should NOT be taken as more authoritative than that contained in the instruction manual which accompanies (or should accompany) the device.
Further, the vast bulk of tips and horns are made of titanium alloy and these instructions apply specifically to that metal, as well as to monel, nickel, and similar "bell metal" alloys. Similar effects have been observed in glass, ceramic, and single-crystal radiating faces.
Another caveat - these instructions do NOT apply to bonded crystal tips, such as sapphire tips; they must be replaced by the factory.
Tip life can be best be extended by polishing the tip (the radiating face, only) with an abrasive paper or cloth; do NOT attempt to lathe turn the face - too much material will be removed. Remember that the tip is part of a finely-tuned resonant body (in effect, a bell) and removing material, by erosion or abrasion, shortens the length and thus raises the natural resonant frequency. Removing too much material may drive the frequency above that which the generator can accomodate and the machine may drop out of resonance. Trying to force a machine to resonate above its frequency limit could destroy the driving circuit or even cause failure of the transducer.
To properly dress a worn tip, do so BEFORE erosion progresses beyond mere matting of the finish. Hold the tip or horn absolutely perpendicular to a piece of fine carbide grit paper or emery cloth (NOT "sandpaper") placed on a hard, flat work surface and work the tip lightly across the grit in a circular pattern. Do NOT rock the tip or score it by bearing down heavily; anything that detracts from a smooth, flat finish will cause accelerated erosion. Similarly, do NOT try to dress a tip by hand polishing with sandpaper or a file. Stop dressing after the matte grey finish is replaced by a finely criss-crossed pattern of fine scratch marks.
Above all, do NOT attempt to dress a severely eroded tip! Replace it.
If the machine is old and does not have automatic tuning, or if it is a middle-generation machine that requires nominal tuning, always retune after dressing a tip.
Those persons interested in SONOCHEMISTRY might wish to look at
Prof. Kenneth S. Suslick's and
Shiga University's Sonochemistry pages.
THUMBS UP! - Support your local police, fire, and emergency personnel!
To contact S. Berliner, III, please click here.
Return to Top of Page